logo
Huis > producten >
Kabelfoutlocator
>
Cable Fault Simulation Device for Accurate Cable Fault Location with Maximum Resistance Measured 10kΩ

Cable Fault Simulation Device for Accurate Cable Fault Location with Maximum Resistance Measured 10kΩ

Productdetails:
Plaats van herkomst: Xi'an Shaanxi China
Merknaam: XZH TEST
Certificering: ISO CE
Modelnummer: XHFZ510-B2
Detailinformatie
Plaats van herkomst:
Xi'an Shaanxi China
Merknaam:
XZH TEST
Certificering:
ISO CE
Modelnummer:
XHFZ510-B2
Hoogspanningskabelfoutsimulatorspanning:
5~25kVDC
Schakelmethode voor hoofdisolatiefouten:
Snap-on type
Materiaal van de foutmodule:
Zuurstofvrij koper
Markeren:

High Light

Markeren:

Maximum resistance 10kΩ Cable Fault Simulation Device

,

Simulation Device Cable Fault Locator

,

Cable fault location Cable Tester

Trading Information
Min. bestelaantal:
1set
Verpakking Details:
Houten verpakking
Levertijd:
5-8 werkdagen
Betalingscondities:
T/T
Levering vermogen:
3000 eenheden/jaar
Productomschrijving
XHFZ510-B2
With accelerated urbanization, urban scale expands and electricity demand rises yearly. Overhead power lines are being replaced by cables. Popularizing and training cable fault detection personnel has long been challenging. Our self-developed electrical test simulation training system, refined from decades of industry experience, simulates all types of power cable faults to facilitate smooth training.

Cable Fault Types:

Open Circuit Fault:An open circuit fault occurs when the cable insulation is normal, but the voltage cannot be transmitted normally due to conductor defects. Examples include a partially broken core or ground wire, a large line resistance at a point in the core, or a broken core. Simple open circuit faults are rare; they usually coexist with low-resistance or high-resistance faults.


Low-Resistance Fault:A low-resistance fault occurs when the cable insulation is damaged and can be directly tested using the "low-voltage pulse method" between phases. This is called a leakage-type low-resistance fault. The resistance value is typically below several hundred ohms. If the resistance is zero, it is called a short circuit fault, a special case of a low-resistance fault.


High-Resistance Fault:A high-resistance fault occurs when the cable insulation is damaged, forming a fixed resistance path, but cannot be directly measured using the "low-voltage pulse method" of a cable fault detector. The resistance value is typically above several hundred ohms. During a DC leakage withstand voltage test on a cable in the field, the leakage current value increases continuously with the applied DC voltage, far exceeding the cable's required specification value. Leakage-related high-resistance faults and low-resistance faults are relative and not strictly distinguishable.


Flashover-related high-resistance faults: Within the cable's pre-test voltage range, when the pre-test voltage reaches a certain value, the cable's leakage current value suddenly increases, significantly exceeding the cable's required specification value. This type of fault is called a flashover-related high-resistance fault. At this fault point, although the cable insulation is damaged, a fixed resistance path is not formed.


Panel Introduction


Cable Fault Simulation Device for Accurate Cable Fault Location with Maximum Resistance Measured 10kΩ 0

The cabinet door is open, as shown in the diagram below: There are 4 fault distances, with a wave velocity of 200 m/s.

Fault Location 1: Approx. 100 meters

Fault Location 2: Approx. 200 meters

Fault Location 3: Approx. 230 meters

Fault Location 4: Approx. 300 meters

T-Connector: Approx. 340 meters

Total Cable Length: Approx. 370 meters

Cable Fault Simulation Device for Accurate Cable Fault Location with Maximum Resistance Measured 10kΩ 1