Product Description
The XHGG502A cable fault locator is a special instrument for measuring and analyzing the condition and fault distance of power cables. It uses an industrial-grade 10.1-inch touch screen all-in-one machine, equipped with simple operating software interface, convenient for human-computer interaction testing; it also uses industrial-grade integrated circuits and components, with a built-in high-capacity lithium battery, ensuring the instrument's stability, reliability, and ease of use.
It combines modern electronic and computer technology to achieve signal filtering, acquisition, data processing, graphics display, and graphics analysis, thereby completing cable speed measurement, cable length testing, and cable fault distance testing. It is suitable for power cables of various cross-sections and media, high-frequency coaxial cables, streetlight cables, and buried wires with low resistance, short circuits, open circuits, and broken circuits, as well as high-resistance leakage and high-resistance flashover faults.
Main Features
- 10.1-inch full-color TFT touch screen display
- Embedded system provides safe, stable, and convenient display and operation.
- Tests cable wave speed, cable length, and fault distance
- Fully automatic continuous sampling and real-time waveform acquisition, timely and accurate
- Automatic test range setting and automatic waveform analysis, and displays test distance
- Full Chinese menu, two operating modes—touch and button coding—simple, convenient, reliable
- Low-voltage pulse method, high-voltage flashover method, and multi-pulse method (8 pulses); waveforms are smooth and easy to interpret
- In the multi-pulse method, the pulse combiner displays 8 sets of high/low voltage waveforms, facilitating automatic distance testing, manual analysis, and distance measurement.
- Powerful data processing capabilities, convenient for waveform file management and archiving
- Massive waveform storage: Stores on-site waveforms with Chinese names, convenient for timely retrieval; can store over 8000 low-voltage pulse and high-voltage flashover waveform records, and over 250 multi-pulse waveform records; waveform files can be imported to PC software via USB.
- Ultra-bright LED backlight, brightness up to 280 nits, resolution of 1024×600, suitable for direct sunlight environments
- Built-in high-capacity lithium battery pack, supports fast charging, can be tested in environments without power supply
- Protection level up to IP54 for the bottom case
Cable Classification and Fault Types Cable Fault Types
- Open-circuit fault:The insulation layer of the cable is normal, but due to a conductor defect, the voltage cannot be transmitted normally—for example, partial breakage of the core wire or ground wire, excessive resistance of a certain point of the core wire, or breakage of the core wire. Pure open-circuit faults are rare; they usually coexist with low-resistance or high-resistance faults.
- Low-resistance fault:Intermittent or continuous fault, due to damage to the insulation layer, can be directly tested with the low-voltage pulse method; the resistance is usually less than a few hundred ohms. If the resistance is zero, it is called a short-circuit fault, which is a special case of a low-resistance fault.
- High-resistance leakage fault:Damage to the insulation layer, forming a fixed resistance path, cannot be directly measured with the low-voltage pulse method; the resistance is usually a few hundred ohms or more.
- High-resistance flashover fault:Within the pre-test voltage range, when the pre-test voltage reaches a certain value, the leakage current suddenly increases, far exceeding the specified value; the insulation is damaged, but a fixed resistance path has not been formed.
Test Procedure
- Analyze the characteristics of cable faults, understand the voltage withstand level and insulation medium of the faulty cable.
- Use the low-voltage pulse function to test all phases of the faulty cable and calibrate the cable's wave propagation speed.
- Select the appropriate test method for preliminary testing of cable faults.
- Accurately measure the fault point, including determining the direction and depth of buried cables, and precisely locating the fault point.
- Analyze the error of the results (measurement error, propagation speed error, interpretation error, and instrument error).
Working Principle Traveling Wave Method
When an electromagnetic wave propagates in a non-uniform transmission line—that is, when the characteristic impedance at a certain point changes—the wave will not only continue to propagate forward but also generate a backward propagation to the test end. This backward propagating wave is called a reflected wave, and this phenomenon is called reflection; the incident wave and the reflected wave together are called a traveling wave. At a short-circuit point, the polarity of the reflected wave is opposite to that of the incident pulse; at an open-circuit point (including the cable end), the polarity of the reflected wave is the same as that of the incident pulse. Therefore, low-resistance faults and open-circuit faults can be easily located based on the polarity of the reflected wave through the low-voltage pulse method. For high-resistance faults, the high-voltage flashover method is used: a high-voltage pulse signal source (high-resistance leakage fault) or a DC high-voltage source (flashover high-resistance fault) generates a flashover discharge at the fault point, generating a reflected signal, which is detected at the test end. The reflected signal is then converted to a digital signal through a high-speed A/D converter and computer control system, stored and processed, and then sent to the display for waveform analysis—completing a rough measurement of the fault distance.
Low-voltage pulse method
In the function settings area, apply a low-voltage pulse signal to the cable under test; the pulse reflects at the fault point, the tester processes the reflected signal and displays the waveform, and the approximate fault distance is determined by analyzing the reflected waveform.
High-voltage flashover method
- Direct flashover method:Mainly used to test high-resistance flashover faults. A DC high-voltage source applies DC voltage to the faulty cable; when the voltage reaches a certain value, the fault point will generate a sudden flashover discharge, generating a reflected signal, which is received by a dedicated sampling device and transmitted to the tester for processing and analysis.
- Impulse flashover method (universal method):primarily used to test high-resistance leakage faults. A high-voltage pulse signal source applies a high-voltage pulse signal to the faulty cable; the pulse passes through the fault point, causing flashover discharge and a reflected signal, which is received by the dedicated sampler and transmitted to the tester for processing and analysis.
Multiple-pulse method
The system includes an integrated high-voltage generator capable of generating a single-impact high voltage, a multiple-pulse generator, a multiple-pulse automatic triggering device and test waveform analysis software. The multiple-pulse generator guides the instantaneous high-voltage pulse onto the faulty phase, ensuring sufficient breakdown at the fault point and extending the arc duration after breakdown. The automatic triggering device then immediately sends out multiple low-voltage test pulses. The first eight test pulses use the short-circuit characteristics at the moment of cable arc breakdown to form eight fault reflection pulses; after the arc extinguishes, eight more test pulses measure the cable's open-circuit reflection waveform, forming eight sets of secondary pulse waveforms. The multiple-pulse method effectively avoids the interference of the large cosine oscillations that occur under high-voltage impact, allowing clear standard echoes resembling a short-circuit fault to be obtained during the relatively stable arc — greatly simplifying the testing procedure.
Technical Specifications
| Item |
Specification |
| Sampling frequency |
1 MHz ~ 400 MHz |
| Low-voltage pulse amplitude |
300 V ±15% |
| Distance measurement range |
≥ 120 km |
| Test range |
100 m / 300 m / 500 m / 1 km / 3 km / 5 km / 10 km / 25 km / 50 km / 100 km |
| Pulse width |
0.1 μs / 0.30 μs / 0.60 μs / 1.20 μs / 2.4 μs / 5.0 μs / 7.5 μs / 10 μs |
| Minimum resolution |
0.07 m |
| Test blind zone |
≤ 10 m |
| Measurement error |
≤ ±(0.5% × L + 1 m), where L is the cable length |
| Power supply |
Rechargeable AC 110 V ~ 240 V, 50 Hz / 60 Hz; built-in 11.1 V lithium battery pack; charging time approximately 2 hours, working time over 5 hours |
| Pulse coupler withstand voltage |
DC 35 kV |
| Operating conditions |
Temperature -20°C ~ +65°C; relative humidity 90%; atmospheric pressure 750 ±30 mmHg |
Instrument Layout & ComponentsThe instrument set consists of the cable fault tester (which uses the low-voltage pulse method, high-voltage flashover method and multiple-pulse method to test and analyse cables), a coupler (used for the multiple-pulse method), a single-Q output line (connects the tester to the cable under test during the low-voltage pulse method), a dual-Q input line (connects the tester and sampler during high-voltage flashover testing), a sampler (receives the high-voltage signal reflected onto the sampling ground), a power cord (charging cable), coupler high-voltage line A (connects the coupler to the cable under test in the multiple-pulse method; plug / unplug only, do not rotate or screw), coupler high-voltage line B (connects the coupler to the high-voltage pulse signal source in the multiple-pulse method; plug / unplug only, do not rotate or screw), a ground wire (coupler ground wire) and a USB cable (for importing waveform files to a computer).
Front panel items adjust the amplitude knob during waveform acquisition to change the amplitude of the acquired waveform
Operation Guide Software main interface
After the boot screen the system operation interface is shown. The main interface is divided into a working-status indicator area, a waveform display area, an instrument parameter display area, a function setting area and an instrument operation area. The working-status area displays "Standby Status" when the instrument is ready and switches to "Sampling Status" when the sampling button is pressed.
The function setting area includes: medium speed (cross-linked, oil-immersed and rubber cable types; cable propagation speed can be customised); operating modes (five methods: pulse, flashover, velocimetry, multiple measurements and megohmmeter); test range (100 m / 300 m / 500 m / 1 km / 3 km / 5 km / 10 km / 25 km / 50 km / 100 km); file processing (save the current waveform, open previously saved waveforms for comparison, and export waveform files to PC software); sample / hold (start and stop sampling; the waveform display area then refreshes in real time); and system settings (set the system time, turn the auto-range function on / off, adjust brightness and turn the operation feedback buzzer on / off).
The waveform display area shows the real-time sampled waveform in the middle, the test results and distance / wave velocity on the right, and the current instrument parameters at the bottom. The instrument operation area provides amplitude adjustment (three levels X1, X2 and X3; can also be adjusted with the panel amplitude knob during sampling), baseline adjustment (in sampling mode, adjust the upper and lower baseline positions with the "baseline up" and "baseline down" buttons), waveform compression (in hold, use the "Waveform Compression" button to compress or expand the waveform), cursor (while holding the distance, press the "Cursor" button and select cursor 1 or cursor 2, then use the left / right keys to adjust the cursor positions, or press and drag the bottom of the cursor; there are 6 levels X1–X6, where a larger number means a greater distance per step) and automatic measurement (in hold or sampling mode, pressing "Automatic Measurement" automatically calculates the distance result).
Low-voltage pulse method
- In the function settings area, select the medium speed, choose low-voltage pulse mode and select an appropriate test range; if automatic range determination is required, check "Auto-range" in the system settings.
- After completing the parameter settings, click "Sampling"; the instrument automatically performs low-voltage pulse sampling. Adjust the "baseline" and "amplitude" as needed and observe the sampled echo so that the waveform has no upper or lower amplitude limits, until the echo amplitude is suitable for analysis.
- Press "Hold" to stop sampling. Use the overall waveform control area to move and compress the waveform until it is in the best state for analysis, then use the cursor to set the distance and interpret the waveform.
- Click "File Processing" to save the current waveform for later viewing and comparison.
High-voltage flashover method
- Select the medium speed, choose high-voltage flashover mode and select an appropriate test range; check "Auto-range" in the system settings if automatic range determination is required.
- After completing the parameter settings, click "Sampling". After the reflected signal is received via the dedicated sampler, adjust the "baseline" and "amplitude" as needed and observe the sampled echo, until the echo amplitude is suitable for analysis.
- Press "Hold" to stop sampling; move and compress the waveform until it is in the best state for analysis, then use the cursor to set the distance and interpret the waveform.
- Click "File Processing" to save the current waveform.
Multi-pulse method
- Select the medium speed, choose multi-pulse mode and select an appropriate test range; check "Auto-range" in the system settings if automatic range determination is required.
- After completing the parameter settings, click "Sampling". After the reflected signal is received via the dedicated coupler, adjust the "baseline" and "amplitude" as needed until the echo amplitude is suitable for analysis.
- The waveform display area shows waveform number 4 by default; if that group is not satisfactory or cannot be analysed, click the "1–8" analog keys on the left of the screen to display the corresponding multiple-pulse group.
- During analysis, the automatic measurement key can be pressed in sampling / hold mode to measure the distance, or the cursor key can be pressed in hold mode for manual analysis and waveform compression.
- Move the cursor to determine the fault distance, keeping it accurately aligned with the leading inflection point of the transmitted pulse and of the fault echo pulse for precise readings.
- Click "File Processing" to save the current waveform.
Precautions
- Read this manual carefully and follow the relevant precautions. Violent impacts to the instrument and unauthorised shutdown are strictly prohibited.
- Connect the test leads correctly, especially the grounding wire and the high-voltage wire.
- When connecting for the high-voltage flashover or multiple-pulse method, the instrument software must not be set to the low-voltage pulse method.
- High-voltage flashover method and multiple-pulse method sampling are strictly prohibited while the instrument is charging.
- When the battery is low, charge it before use. The instrument is AC / DC dual-use with a built-in high-capacity lithium battery; if it is not used for a long time, charge and maintain it about every 2 months to prevent the battery from being depleted and damaged by self-discharge.
- Before use, check that the power supply is sufficient to prevent the industrial control computer from malfunctioning due to insufficient power — repeated shutdowns / restarts may lead to system file corruption (1 hour of charging provides 2.5 hours of standby; 2 hours of charging fully charges the battery from zero).
- When the instrument is used only for low-voltage pulse method testing, it can be powered by AC 220 V; it is strictly forbidden to connect AC 220 V for high-voltage flashover method or multiple-pulse method sampling tests.
- The instrument is a highly precise electronic device and must not be disassembled by non-professionals; handle it with care during transport, and rough handling or impact is strictly prohibited.
- If the instrument malfunctions, contact the dealer or the company immediately. Damage caused by human error will void the instrument warranty.
- During low-voltage pulse testing, confirm that there is no residual electricity in the cable itself.
After-Sales Service
The instrument is covered by a one-year warranty from the date of purchase for product quality issues, and lifetime maintenance and technical services are provided. If you find any abnormality or malfunction in the instrument, please contact us so that we can arrange the most convenient and effective solution for you.
FAQ
Q1. What cable faults can the XHGG502A test?
It tests low-resistance, short-circuit, open-circuit and broken-circuit faults, as well as high-resistance leakage and high-resistance flashover faults. It is applicable to power cables, high-frequency coaxial cables, streetlight cables and buried wires of various cross-sections and media. Low-resistance and open-circuit faults are judged with the low-voltage pulse method, while high-resistance faults are tested with the high-voltage flashover method.
Q2. What are the test methods, range and accuracy?
The instrument supports the low-voltage pulse method, the high-voltage flashover method (direct flashover and impulse flashover), the multiple-pulse method (8 pulses) and velocimetry. Sampling frequency is 1 MHz–400 MHz, the low-voltage pulse amplitude is 300 V ±15%, the distance measurement range is ≥ 120 km, the test range is 100 m to 100 km, the minimum resolution is 0.07 m, the test blind zone is ≤ 10 m and the measurement error is ≤ ±(0.5% × L + 1 m).
Q3. How is it powered, and how should the battery be cared for?
It charges from AC 110 V–240 V, 50 Hz / 60 Hz and works from a built-in 11.1 V lithium battery pack; charging takes approximately 2 hours and working time is over 5 hours. High-voltage flashover and multiple-pulse sampling are strictly prohibited while charging, and if the instrument is not used for a long time it should be charged about every 2 months.
Q4. Is the coupler included for the multiple-pulse method?
Yes. This configuration is supplied with the coupler, so the multiple-pulse method can be used directly. Used with the pulse coupler, the multiple-pulse method displays 8 sets of high / low voltage waveforms for comparison, making automatic distance testing, manual analysis and distance measurement easier. Note that the coupler connection lines must only be plugged / unplugged, never rotated or twisted.
Q5. What is included in the package, and what about after-sales service?
The packing list includes the cable fault tester (1 unit), power cord (1 pc), single Q line (1 pc), double Q line (1 pc), sampling box (1 pc), coupler host (1 unit), transparent grounding wire (1 pc), coupler high-voltage line A (1 pc), coupler high-voltage line B (1 pc) and USB communication cable (1 pc). The instrument is covered by a one-year warranty for product quality issues from the date of purchase, plus lifetime maintenance and technical services